Merk :
MTLOnderdeel nummer :
8922-RB-ISGewicht :
0.345 kgDimensie :
10 (w) x 160 (h) x 42 (d) mmLand van herkomst :
USAHS-code :
8537101190Beschrijving :
Railbus Isolator
Get Price Here:
Sales Manager: Frida
Phone/Whatsapp: +86 15359408275
Email: sales5@mooreplc.com
Basic Information
Manufacturer: MTL Instruments (Eaton)
Product Family: MTL8000 Series I/O Infrastructure
Function: Galvanic Isolation Barrier for Railsus (MTL8000 Backplane Bus)
Primary Application: Isolation of IS field wiring modules from non-IS control network segments.
Product Description
The 8922-RB-IS is a passive infrastructure component designed to segment the MTL8000 series backplane bus. It provides galvanic isolation between the "Safe Area" Railbus (connected to the controller/gateway) and the "Intrinsically Safe" Railbus (powering IS I/O modules like the 8220-DI-IS).
Technical Specifications
|
Section |
Parameter (English) |
Specification / Value |
|
Bus Interface |
Safe Area Side (2/2) |
Female In Connector |
|
|
IS Railbus Side (2/1) |
Male Out Connector |
|
|
Max Node Addressing |
1-32 or 1-64 (Configurable) |
|
Power Requirements |
Safe Area Railbus (12V) |
50 mA (Max) |
|
|
IS Railbus (12V) |
60 mA (Max) |
|
|
Total Power Dissipation |
1.2 W (Max) |
|
Isolation & Safety |
Safe Area Um |
250 V |
|
|
IS Railbus Un |
18 V |
|
|
Location of Module |
Class I, Div 2 / Zone 2, IIC T4 |
Application Fields
Chemical & Petrochemical:Bulk monitoring of manual valves, pressure switches, and level switches in storage tank farms.
Turbine Control Systems:Interface for vibration sensor alarm contacts (proximity probes) with LFD to ensure loop integrity.
Fire & Gas Panels:Monitoring of manual call points and smoke/heat detectors located in hazardous processing zones.
Rail & Transportation:Status feedback from track-side signaling equipment where intrinsic safety is mandated.
Frequently Asked Questions - 8922-RB-IS
Q: Does the 8922-RB-IS require an external 24V power supply?
A: No. The module is bus-powered. It draws a small quiescent current (50mA / 60mA) directly from the 12V Railsus backplane on both sides of the barrier. No separate field wiring is needed for power.
Q: What is the difference between the "2/2 Side" and "2/1 Side"?
A:
2/2 Side: Connects to the Controller/Host segment of the bus. This side is not intrinsically safe and typically carries the higher Um (250V) rating.
2/1 Side: Connects to the Field I/O Module segment. This side is protected and provides power to IS modules like the 8220-DI-IS.
Q: Can I use more than one 8922-RB-IS on a single node?
A: Yes. You can use multiple isolators to create separate protected branches. However, the isolator does not act as a repeater for distance extension; it acts as a barrier. The maximum number of modules on the IS side is limited by the 60mA available current from the isolator's 2/1 side.
Company Service
|
Fast delivery (1-2 days will ship out for in stock products) |
|
Rich experience (Established more than 10 years) |
|
Large inventory ( Various brands and overseas warehouse) |
● Distributed control system (DCS)
● Programmable Controller
● Remote input / output module (RTU)
● Industrial PC (IPC)
● Industrial low-frequency screen
● Lowcapacity hard drives for industrial use SCSI (50,68,80Pin)
● AnyBus (Gateway)
● Human-machine interface
● Industrial control related ancillary products
Other Options
|
Honeywell |
Emerson |
PLC |
|
10313/1/1 |
KJ3002X1-BB1 12P0683X082 |
2711C-K3M |
|
125840-01 |
KJ3002X1-BB1 12P0683X092 VE3006 |
2711-K10C15L1 |
|
135489-01 |
KJ3002X1-BC1 12P0681X072 VE4003S1B2 |
2711-K3A17L1 |
|
2MLF-RD8A |
KJ3002X1-BC1 12P0681X082 VE4003S1B2 |
2711-K3A5L1 |
|
30735974-002 |
KJ3002X1-BC1 12P0681X092 |
2711-K5A2 |
|
3500/15 AC 127610-01 |
KJ3002X1-BC1 12P0681X092 VE4003S1B2 |
2711-K5A2X |
|
38500143-200 |
KJ3002X1-BE1 12P0682X052 |
2711-K5A5X |
|
38500148-300 |
KJ3002X1-BF1 12P1732X042 VE4003S6B1 |
2711-K6C10 |
|
51109693-100B |
KJ3002X1-BF1 12P1732X082 VE4003S6B1 |
2711-K9C1 |
|
51195066-100 |
KJ3002X1-BF1 12P1732X082 VE4003S6B1 |
2711P-B6C20D 2711P-RN10C |
|
51195096-200 |
KJ3002X1-BF1 12P1732X082 VE4003S6B1 |
2711PC-T10C4D1 |
|
51195153-001 |
KJ3002X1-BG2 12P1731X032 |
2711PC-T10C4D8 |
|
51195153-005 |
KJ3002X1-BG2 12P1731X032 VE4003S5B1 |
2711P-K15C4A8 |
|
51195153-902 |
KJ3002X1-BG2 12P1731X062 |
2711P-RC3 |