Bently Nevada 200150 vs 200155 vs 200157: Why 100 mV/g Is Not Enough
Three accelerometers may share a nominal sensitivity while requiring different monitoring channels. Follow the signal path before ordering a replacement.
A replacement decision starts with the machine and the installed monitoring channel—not with “100 mV/g” alone. The piezoelectric element in a 20015x sensor generates a charge under vibration; its electronics convert that charge to a differential voltage proportional to acceleration. The receiving interface and channel configuration determine how that signal is used. Baker Hughes explains the sensing principle in its 2021 Orbit article.
The manufacturer lists 100 mV/g nominal sensitivity for all three base sensors, but different ProTIM channel options and applications. The shared sensitivity is a specification—not an interchangeability approval.
Start with the monitoring objective
Moore product links identify complete listed order numbers; channel guidance comes from the manufacturer’s base-model datasheet.
Replacement warning: Baker Hughes cautions that using a 200155 or 200157 in place of a 200150 without checking the system may lead to faulty readings. Do not infer compatibility from the model family or nominal sensitivity.
Trace the complete signal path
A correct sensor cannot compensate for the wrong cable, excitation or receiving channel.
The 20015x family provides a differential voltage output. Do not assume a PLC’s 4–20 mA input or a generic two-wire IEPE input is suitable without checking the actual interface.
The 200155 and 200157 sensor specifications extend to 10 kHz, but 200200/200250 ProTIM acceleration-to-velocity circuitry attenuates frequencies above 1 kHz.
Check the cable and mounting code
These are purchasing details, not accessories to guess after the order is placed.
Moore lists the 200152-15-00 accelerometer interface cable. Baker Hughes identifies the 200152 as a standard interface cable with a connector on the accelerometer end only. In this order number, 15 means 15 metres and 00 specifies a standard coupling nut. Confirm the other-end termination against the site drawing.
A 15-metre cable is close to the manufacturer’s maximum permitted length for the 200155. Check the routed length and any additional cable sections before specifying it.
00: no stud supplied. 02: 3/8-24 to 3/8-24 UNF stud. 22: 3/8-24 to M8×1.25 stud.
Suffix hold point: The cited ordering table does not establish the meaning of CN on the Moore-listed products. Keep the full order number and confirm the suffix against the nameplate and applicable approval documentation.
Recommended Moore-listed models
Use the arrows to compare three accelerometers and the matching cable listing. Each button opens the exact product-detail page in a new tab.

200150-02-CN
Moore-listed configuration for general machinery casing-vibration applications. Verify the installed ProTIM interface and the complete suffix before ordering.
View exact product details
200155-00-CN
Moore-listed low-frequency configuration for appropriate slow-running machinery. Confirm the required measurement range, cable length and channel option.
View exact product details
200157-22-05
Moore-listed configuration for applications requiring acceleration enveloping. Do not select it from 100 mV/g sensitivity alone.
View exact product details
200152-15-00
Moore-listed 15-metre interface cable with the accelerometer-end connector. Confirm the field termination and total installed cable length.
View exact product detailsFrequently asked questions
Short answers for purchasing and maintenance teams. Open one question at a time for the key check.
Can 200155-00-CN directly replace 200150-02-CN?
Not from sensitivity alone. Their intended frequency focus and ProTIM channel options differ, so the installed interface and application must be checked before substitution.
Can 200157-22-05 be chosen only because it is rated 100 mV/g?
No. The 200157 is intended for acceleration-enveloping applications and requires the appropriate monitoring channel. The complete signal path determines suitability.
Does 200150-02-CN connect directly to a PLC 4–20 mA input?
No. The 20015x accelerometers provide a differential voltage output and require the correct excitation and monitoring interface; they are not two-wire 4–20 mA transmitters.
Which ProTIM channel should be checked for each base sensor?
The manufacturer lists channel option −01 for 200150, −05 for 200155 and −06 for 200157. Always verify the installed module, firmware and site configuration.
What should be checked before ordering 200152-15-00?
Confirm the accelerometer-end connector, field termination, 15-metre route and total installed cable length. For 200155, compare the full route with the manufacturer’s cable-length limit.
What information helps Moore quote the exact model?
Send the complete sensor or cable order number, the installed interface/channel, mounting requirement, quantity and destination. A clear nameplate photo is helpful when available.
Send the signal path, not just “100 mV/g.”
Share the complete order numbers and installed channel details. Moore can then check the requested item against its listed product record and prepare an accurate quotation.